My Best Sourcing
1000W 2000W MPPT Solar Inverter DC22-65V/ 45V-90V or to AC110V220V Can Work with PV Panels or Battery with Export Limit Function
1000W 2000W MPPT Solar Inverter DC22-65V/ 45V-90V or to AC110V220V Can Work with PV Panels or Battery with Export Limit Function
SPECIFICATIONS
Brand Name: Jesudom
Hign-concerned Chemical: None
Type: DC/AC Inverters
Origin: Mainland China
Size: 430*310*160mm/540*310*160mm
Output Frequency: 50HZ60HZ
Output Type: SINGLE
is_customized: Yes
Output Power: 1 - 200KW
Weight: 5.5KG/7KG
Model Number: SUN-1000GTIL2-LCD/SUN-2000GTIL2-LCD
Certification: CE
Certification: RoHS
Max.Output Power: 1000-2000W
Output Wave: Pure Sine Wave
MPPT Efficiency: 99%
Input Voltage Range: 22-60VDC/45-90VDC
Nominal Voltage: 110VAC/230VAC
Type: Solar Grid Tie Inverter
Certificata: CE & Rohs
Warranty: 1 Year
1000W 2000W MPPT Solar Inverter DC22-65V/ 45V-90V or to AC110V220V Can Work with PV Panels or Battery with Export Limit Function
Package Include:
1. Piece MPPT Inverter
2. Clamp Sensor:with 3meters/10meters cable/20meters (choose)
3. A Wifi Plug with Cable(choose)
4. An AC Power Cable
5. Piece User Manual (English)
Feature for the Solar grid tie inverter:
Easy installation, can be paralleled on AC side.
Nice LCD display various parameters including input voltage, output power, temperature,form etc.
Can be integrated with internal limit function.
Wifi wireless communication extended interface, enable inverter power production data on PC web or phone APP.
RS485 extended interface serviceable.power curve, output sine wave collect by wifi plug and monitor.
Work with solar panels/work with battery.
INPUT DATA(DC) |
SUN-1000G2-M/H |
SUN-2000G2-M/H |
Input Voltage Range |
22-65VDC/45-90VDC |
45-90VDC |
Maximum Input DC Voltage |
65V/90V |
90V |
Peak Power Tracking Voltage |
25V-60V/50V-90V |
50V-90V |
Operating DC Voltage Range |
22V-65V |
45V-90V |
Start-up Voltage |
25V/49V |
49V |
OUTPUT DATA(AC) | ||
Maximum Output Power |
1000W |
2000W |
Nominal Voltage |
110VAC/230VAC |
230VAC |
Nominal Voltage Range |
95-140V/185-265V |
185-265V |
Frequency Range |
47.5-51.5 for 50gz,59.3-60.5 for 60hz |
|
Power Factor |
>0.95 |
|
Output Waveform |
Pure Sine Wave |
|
CHARACTERISTIC DATA | ||
MPPT Effeciency |
99% |
|
Over Current Protection |
Yes |
|
Over Temperature Protection |
Yes |
|
Reverse Polarity Protection |
Yes |
|
Anit- Island Protection |
Yes |
|
Stackable |
Just for AC Output |
|
Operating Temperature Range |
-20℃~45℃ |
|
Storage Tmpeperature Range |
-40℃~65℃ |
|
Current THD |
<5% |
|
Voltage THD |
<5% |
|
Standard |
CE,EN50438 |
|
Efficiency |
92% |
|
Features | ||
Net Weight |
3.6KG |
5.5KG |
Gross Weight |
5.0KG |
6.5KG |
Dimension(Package) |
430*310*160mm |
540*310*160mm |
Optional Part :
Wifi Port for MPPT 1000W/2000W NEW SUN Solar Grid Tie Inverter
Web / Mobile Phone App on Line Monitoring
NOTE : It will be built-in side the inverter .
Product description :
How to use the grid tie inverter ?
1 unit inverter installation / more units inverters in parallel . the inverter AC output can be connected in the AC plug of grid in the house .
2-1. Using Grid Tie Inverter With Limiter Model
2.1 The Grid Tie Inverter with Limiter delivers only the power needed by the load and prevents delivering excess power hence avoids excess power in going back to the Grid.
2.2 The heart of the Grid Tie Inverter with Limiter is the Limiter Module (LM). The LM continuously sampled the power needed by the load through the current sensor connected after the Main Circuit Breaker. The LM then will process the signal. It then sends signal to Grid Tie Inverter how much power to deliver to the load in real time.
2.3 The user, after installing and connecting the GTIL correctly, need not do anything and the unit will do its work automatically.
3. Installation of GTIL With Internal Limiter
3.1 This installation is not require an additional limiter module,Installation is much easier.Clamp the current sensor cable to the hot wire to measure the current,the internal limiter will auto detect the load power and control the inverter output power,excess power will be well controlled.
3.2 External protective device including dc and ac SPD(Surge protection device),dc and ac breaker,etc is recommended to installed in the system.
4.Limiter Setting on the LCD of the inverter:
The GTIL include three working mode:
Work as normal GTI without power limitation.
Work under Internal limiter mode
Work under External limiter mode,
Pls make your setting on the LCD and save it,details setting operation,pls read the GTI manual.
5 Battery Discharge Power Mode
New upgraded firmware enable battery or solar limiter current and power model.
6 Limiter Module Specification
1. Clamp sensor- Max 100A
2. Wattmeter- Max 9999w
3. Terminal Block-Max 20A
4. Receptacle- max 2000w
5. Clamp sensor signal- 5v AC max mA
6. DC signal Cable- 5v DC, max mA
Picture showing:
Dear customers friends,Please do not fill in the island address when you choose the Poland warehouse for shipment.Because the local logistics company will not send it to the island address.Please fill in the mainland address.Thank you for your order.